What we found running 9 public bid sets through takeoff
Of 9 public Missouri bid sets (318 pages), 5 had at least one partition type our engine could read, and 8 had a wall-plan sheet we could find. Auto-match on the 3 sets we ran end to end was 0%, 0% and 0.3% of wall length, against 68.9% on Freeport Square. Wall-type legends are often drawn, not typed, so a hand check is part of any honest takeoff. Your first plan set is free, no card.
The data: 9 public bid sets
Each row is one open Missouri state bid set, scanned by our engine in October 2026. Counts are sheets or wall types, not feet.
| Bid set | Pages | Wall-plan sheets | Legend sheets detected | Sheets with walls measured | Partition types read | CMU types read |
|---|---|---|---|---|---|---|
| C2419-01 | 23 | 1 | 3 | 1 | 7 | 8 |
| C2505-01 | 9 | 1 | 0 | 1 | 0 | 1 |
| C2512-01 | 133 | 4 | 9 | 13 | 20 | 16 |
| F2402-01 | 26 | 1 | 2 | 1 | 4 | 3 |
| O2604-01 | 25 | 1 | 2 | 2 | 2 | 4 |
| R2506-01 | 27 | 1 | 1 | 0 | 0 | 0 |
| R2607-01 | 7 | 0 | 0 | 0 | 0 | 0 |
| R2609-01 | 32 | 1 | 4 | 0 | 0 | 0 |
| X2337-01 | 36 | 2 | 5 | 1 | 2 | 1 |
| Total | 318 | 12 | 26 | 19 | 35 | 33 |
- Wall-plan sheet found: 8 of 9 sets. The 7-page set (R2607-01) had none our engine could identify.
- Legend sheet detected: 7 of 9 sets. Detected means flagged as a legend, not matched to walls.
- At least one partition type read: 5 of 9 sets (56%).
- Walls measured on at least one sheet: 6 of 9 sets. Only 19 of 318 sheets (6%) had walls measured.
- Wall length per sheet: not published. Raw geometry was not matched to the legend, so an average would mislead.
Auto-match on the sets we ran end to end
- Moberly kitchen (C2419-01): 0% of 3,571 LF auto-matched.
- Judiciary Library (O2604-01): 0% of 4,466 LF.
- Director's House (F2402-01): 0.3% of 674 LF.
- Freeport Square Apartments (21 pages, internal test): 68.9% of walls auto-matched, 99.8% after one "Confirm all." An earlier run of the same set resolved 41.3% of wall length, so the number moves with the engine and the measure used.
- UNC Charlotte public renovation set: 5% resolved. Partition tags like 0S3B-S were not decoded at the time.
Why auto-takeoff needs a hand check
The failures were not random. On the three Missouri sets, partition types were drawn as graphic detail sections, or as coded tags with a single typed row such as "M6 CMU 5-5/8", so there was no legend text to match. On Freeport Square the wall-type legend shares a sheet with the door schedule, and the two tables extract interleaved. When the type cannot be matched, ReadMyBlueprint labels the wall "SPEC UNKNOWN, confirm manually" instead of guessing. That is why a person reads the partition sheets and confirms types before a bid goes out. See how to read a wall-type legend and how wall-type matching works.
Methodology and limits
- Sample: 9 public Missouri state bid sets, plus Freeport Square and one UNC Charlotte set from our internal tests. No customer-uploaded plan was used in this dataset.
- Not counted line by line in full. The 9-set table is engine output on public sheets. Only the Moberly, Library and Director's House sets were run end to end and checked against the drawings.
- Selection bias: the sets are open state bids with interior wall work, one state, one owner type. They do not represent private commercial plans.
- Engine versions differ: the October scans and the Freeport figure were not all run on the same build.
- Not checked: wall length per sheet, accuracy against an estimator's finished takeoff on the Missouri sets.
See also our accuracy page and the Freeport Square test in full.
FAQ
How many public bid sets had a readable wall-type legend?
Five of the 9 public Missouri bid sets (56%) had at least one partition type our engine could read from the plans. Seven of 9 had a sheet flagged as a legend, but a flagged legend is not the same as one we could match. Sample is small: 9 sets, 318 pages.
What is the auto-match rate on public bid sets?
On the 3 sets we ran end to end on 2026-10-07, auto-match was 0%, 0% and 0.3% of wall length. On the one fully verified set, Freeport Square (21 pages), 68.9% of walls auto-matched and 99.8% after one Confirm all. Four data points is not a benchmark, and the spread is the finding.
Why does auto-takeoff need a hand check?
Wall types on many public sets are drawn as graphic details or coded tags instead of text a reader can match. When the legend cannot be matched, the software labels the wall unknown rather than guess, and a person confirms the type.
What is the average wall length per sheet?
Not published. Our engine's raw wall geometry on these sets is not matched to the legend, so a per-sheet average would mislead. We report it as not checked rather than estimate.
Does this include customer plans?
No. Only public Missouri state bid sets and our own internal test plans. No customer-uploaded plan is used in this dataset.
Can I try it on my own plan set?
Yes. Your first plan set is free, no card needed, and the product tour at /tour shows the flow first.
Your first plan set is free
No card needed. Or see it first on the product tour. Trade page: drywall takeoff.
Upload your plan set free