Interior scope takeoff from one PDF: partitions, flooring, ceilings and paint
From one PDF, ReadMyBlueprint takes off the partitions: wall length, area and board by wall type, traced to each wall. Flooring by finish, ceilings by type and paint are not measured automatically, so this page shows which sheet each one comes from and how to carry them in the same bid without double counting. First plan set free, no card.
Upload your plan set free No card needed.
What the software does, and what stays by hand
| Scope | Comes from | In ReadMyBlueprint? |
|---|---|---|
| Partitions by wall type | Floor plans and the wall-type legend | Yes. Length, area, studs, track, board and insulation by wall type. |
| Doors, windows, one-off items | Floor plans, door schedule | Not auto-detected. Add with a click or Manual count. |
| Flooring by finish | Finish plan or finish schedule | Not auto-measured. Trace areas with the hand-measure tool, or measure elsewhere. |
| Ceilings by type | Reflected ceiling plan (RCP) | No. RCP sheets are set aside and listed so walls are not counted twice. |
| Paint | Finish schedule plus wall area | No. Wall area can feed your own paint arithmetic. |
That is the boundary on the features page: it counts walls, framing, drywall, insulation and block. Painting is not in the list. If you want one tool that measures every interior trade, this is not it; pick on that basis.
One PDF, four kinds of sheet
An interiors set mixes sheet types, and each scope lives on a different one. Sorting the sheets first is the fastest way to avoid counting a wall twice. See also which plan sheets to use for drywall takeoff.
- Floor plans and the partition legend: partitions by wall type. Upload the whole PDF; auto-detect reads the legend text and scale on its own and sets ceiling plans, elevations and details aside.
- Finish plan or room finish schedule: one row per room, with floor finish, base, wall finish and ceiling. This one table drives flooring, paint and ceiling type at once.
- Reflected ceiling plan: ceiling areas by type, heights and bulkheads. Method on ceiling drywall takeoff.
- Details and sections: soffit drops, wall base conditions, and what the legend leaves out.
Partitions by wall type
Group by wall type, not by total wall length. A corridor wall in two layers of fire-rated board and a plain single-layer partition use different board counts at the same length. The legend steps are in how to read a wall type legend and wall-type matching. Walls drawn as EXISTING in the legend are set aside, not counted as new work, which matters on a tenant fit-out. Anything it cannot match is labeled, never guessed.
Flooring by finish
Take flooring from the finish schedule rows, not from floor plan hatching alone. Make one line per finish (carpet tile, LVT, sealed concrete, tile) with area per room, and carry base by linear foot as its own line. A transition strip at a door is a count, not an area. The hand-measure tool lets you trace an area on a plan page, with points snapped to the sheet's own vector endpoints; the item is labeled "Hand-measured" in the export. We have not published a flooring test, so check every traced area against the room dimensions on the sheet.
Ceilings by type
Separate lines for gypsum board hard lids, acoustic tile and open-to-structure. Tile and grid are often another trade's scope, so read the RCP legend and your contract before you price them. Soffits and bulkheads need the detail for the drop and width. Full method: ceiling drywall takeoff.
Paint
Paintable wall area is partition area minus openings, for each side the finish schedule says gets paint, plus any painted ceilings. The wall area comes from the partition takeoff; the openings and the finish per room are yours. Start from ReadMyBlueprint's wall area for both sides, then remove sides that are tiled, covered or left unpainted per the schedule. Paint is not a feature here, so this is a spreadsheet step, starting from the CSV or Excel export.
Proof, with its limits
On the Freeport Square set (21 pages, apartments), 68.9% of walls auto-matched to the plan's own legend and 99.8% resolved after one "Confirm all". That is one plan set and it covers partitions only. We have no verified test for flooring, ceilings or paint. On that set the legend shares a sheet with the door schedule, so the text layer came out scrambled and most wall types were flagged for a person. See the full test and accuracy.
FAQ
Can I take off flooring, ceilings and paint from one PDF?
You can pull the quantities from one PDF, but ReadMyBlueprint only measures the partitions automatically. Flooring, ceilings and paint come from the finish schedule and reflected ceiling plan, and are done by hand or with the hand-measure tool.
Does ReadMyBlueprint measure paint?
No. It returns wall area by wall type, which you can use as the starting point for your own paint arithmetic.
Does it read the reflected ceiling plan?
No. It sets RCP sheets aside so walls are not counted twice, and tells you which sheets it skipped.
What do I need to upload?
A digital PDF plan set exported from CAD or Revit. Scanned plans are counted too: upload them or send them, and the counts come back the same way.
Your first plan set is free
No card needed. Upload a digital PDF and check the counts against the sheets. Or see it first on the product tour.
Upload your plan set freeRelated: Drywall takeoff from PDF plans · Ceiling drywall takeoff · Tenant improvement drywall takeoff · Features and limits · Product tour